MasterCraft X-15 Installationshandbuch Seite 23

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 26
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 22
Installaon manual and user guide MasterCra / Holland Marine Parts 23
12V
Contactor support on pump unit
Baery Cable connecon
to Pump unit:
- Baery Posive to
free contact at contactor relay
- Connect A cable from
pump unit to baery negave
Note:
Baery cable
length max.
1m/3.3
Note:
Use a baery with
high cold cranking
amps.
Note:
Do not use the dedicated Jet Thruster
baery to power the 12V control circuit.
F
E
D
C
G (-)
GROUND
(+)
12V
B
A
+
joysck
Posive / Electrical Air valve to: F
Negave / Electrical Air valve to: G
G: Connect with baery minus
Switch A and B wires at contactor support
if joysck control needs to be reversed.
A
B
to joysck
to valve
Fuse 425A
Fuse 15A
+ Ignion
- Ground
Seitenansicht 22
1 2 ... 18 19 20 21 22 23 24 25 26

Kommentare zu diesen Handbüchern

Keine Kommentare